Allied Telesis AT-8100 Series User Manual
Page 695
AT-8100 Switch Command Line User’s Guide
695
The management software modules are listed in Table 81 on page 705.
Confirmation Command
Examples
This example configures the buffered log to save only those event
messages that have a severity level of 0 or 4:
awplus> enable
awplus# configure terminal
awplus(config)# log buffered level 4
This example configures the buffered log to save only those event
messages that are generated by IGMP snooping (IGMPSNOOP), LACP
and port configuration (PCFG):
awplus> enable
awplus# configure terminal
awplus(config)# log buffered program igmpsnooping,lacp,
pconfig
This example configures the buffered log to save those event messages
that have a severity level of 0 or 4, that are generated by 802.1x port-
based network access control (PACCESS) and 802.1q GARP, and that
have the text “port” in the messages:
awplus> enable
awplus# configure terminal
awplus(config)# log buffered level 4 program paccess,garp
msgtext port
4
Warning message
6
Informational message
7
Debug message
Table 79. Event Message Severity Levels (Continued)
Severity
Description