293

SHOW POWER-INLINE INTERFACE

Syntax

show power-inline interface

port

Parameter

port

Specifies a port. You can display more than one port at a time.

Mode

Privileged Exec mode

Description

Use this command to display the PoE information on the ports. An
example is shown in Figure 66.

Figure 66. SHOW POWER-INLINE INTERFACE Command

This command displays a subset of the information the SHOW POWER-
INLINE command displays. The fields are described in Table 24 on
page 289.

Example

This example displays PoE information for ports 1 to 4:

awplus# show power-inline interface port1.0.1-port1.0.4

Interface Admin

Pri

Oper

Power

Device Class

Max(mW)

port1.0.1 Disabled Low

Disabled 0

0

15400 [C]

port1.0.2 Enabled

High

Powered

3840

Phone

1

5000 [U]

port1.0.3 Enabled

Crit

Powered

6720

AccessPt 2

7000 [C]

port1.0.4 Disabled Low

Disabled 0

0

15400 [C]