Show power-inline command – Allied Telesis AT-8100 Series User Manual

Page 289

background image

AT-8100 Switch Command Line User’s Guide

289

Table 24. SHOW POWER-INLINE Command

Field

Description

Nominal Power

The switch’s total available power in watts (W).

Power Allocated

The available power in watts (W) for PDs. This
value is updated every 5 seconds.

Actual Power
Consumption

The current power consumption in watts (W) of the
PDs. This value is updated every 5 seconds.

Operational
Status

The operational status of the power supply units
(PSU) in the switch. The status can be one of the
following:

On: The units are powered on.

Fault: One of the power supplies has
encountered a problem.

Power Usage
Threshold

The SNMP power-inline trap threshold. A SNMP
trap is transmitted if the power requirements of the
switch and PDs exceed the threshold. This
parameter is set with “POWER-INLINE USAGE-
THRESHOLD” on page 286.

PoE Interface

A table of port PoE information.

Interface

The port number.

Admin

The status of PoE on the port. The status can be
one of the following:

Enabled: PoE is enabled. The port can transmit
power to a PD. PoE is enabled with “POWER-
INLINE ENABLE” on page 282.

Disabled: PoE is disabled. The port does not
supply power to a PD, but it does forward
network traffic. PoE is disabled with “NO
POWER-INLINE ENABLE” on page 274.

Pri

The port’s PoE priority level. This parameter is set
with “POWER-INLINE PRIORITY” on page 284.
The priority level can be one of the following:

Low: The lowest priority level. Default level.

High: The higher priority level.

Crit: Critical, the highest priority level.