AT-8100 Switch Command Line User’s Guide

515

Figure 109. Group Link Control Example 3

When a link on an upstream port is reestablished, the switch automatically
reactivates the downstream counterpart. Referring to the example, when
the link on port 17 is reestablished, the switch enables port 24 again.

A link control group can have more than one upstream or downstream
port. This enables it to support static port trunks and LACP trunks. When a
group has two or more upstream ports, all of the upstream ports must lose
connectivity before the switch disables the downstream ports. This is
illustrated in Figure 110 on page 516 where a link control group on switch
3 has two upstream ports, ports 17 and 20, and two downstream ports,
port 24 and 25. If connectivity is lost on just port 17, the downstream ports