Chapter 12: Power Over Ethernet Commands

290

Example

This example displays PoE information about the switch and ports:

awplus# show power-inline

Oper

The PoE operating status of the port. The possible
status are listed here:

Powered: The port is transmitting power to the
PD.

Denied: The port is not transmitting power to
the PD because the switch has reached its
maximum power capacity.

Off: PoE is disabled on the port.

Fault: The switch is exceeding the total
available power.

Test: The port is in a test mode.

Power

The port’s current power consumption in milliwatts
(mW).

Device

The port’s PD description. This parameter is set
with “POWER-INLINE DESCRIPTION” on
page 281.

Class

The PD’s class PD. See “PD Classes” on page 258
for details.

Max (mW)

The port’s maximum power limit in milliwatts (mW)
and how the limit was set. The methods are listed
here:

[U]: The power limit was set with “POWER-
INLINE MAX” on page 283.

[L]: The power limit was supplied by LLDP.

[C]: The power limit was set according to the
PD’s class.

Table 24. SHOW POWER-INLINE Command (Continued)

Field