Allied Telesis AT-8100 Series User Manual
Page 1289
AT-8100 Switch Command Line User’s Guide
1289
This command is also used to remove parameter values from existing
LLDP-MED coordinate location entries. To remove parameters, use the
NO forms of the parameters listed in Table 131.
To assign coordinate location entries to ports, refer to “LLDP LOCATION”
on page 1267.
To remove a coordinate location entry, use “NO LOCATION” on
page 1299.
Confirmation Command
altitude floors
Altitude in number of floors. The
range is -2097151.0 to 2097151.0.
The value for this parameter must
be specified between the two
keywords, as shown here:
altitude n floors
altitude meters
Altitude in meters. The range is
-2097151.0 to 2097151.0 meters.
The parameter accepts up to eight
digits to the right of the decimal
point. The value for this parameter
must be specified between the two
keywords, as shown here:
altitude n meters
alt-resolution
Altitude resolution as the number
of valid bits. The range is 0 to 30
bits.
datum nad83-mllw|nad83-navd|
wgs84
The geodetic system (or datum) of
the coordinates. The selections
are:
nad83-mllw - Mean lower low
water datum 1983
nad83-navd - North American
vertical datum 1983
wgs84 - World Geodetic
System 1984
Table 131. LLDP-MED Coordinate Location Entry Parameters (Continued)
Parameter
Value