beautypg.com

Allied Telesis AT-8100 Series User Manual

Page 295

background image

AT-8100 Switch Command Line User’s Guide

295

PoE admin

The status of PoE on the port. The status can be
one of the following:

Enabled: PoE is enabled. The port can transmit
power to a PD. PoE is enabled with “POWER-
INLINE ENABLE” on page 282.

Disabled: PoE is disabled. The port does not
supply power to a PD, but it does forward
network traffic. PoE is disabled with “NO
POWER-INLINE ENABLE” on page 274.

Priority

The port’s PoE priority level. The priority level is set
with “POWER-INLINE PRIORITY” on page 284.
The priorities are listed here:

Low: the lowest priority level. This is default
level.

High: the higher priority level.

Crit: the critical, or highest priority level.

Detection status

The PoE operating status of the port. The possible
status are listed here:

Powered: The port is transmitting power to the
PD.

Denied: The port is not transmitting power to
the PD because the switch has reached its
maximum power capacity.

Off: PoE is disabled on the port.

Fault: The switch is exceeding the total
available power.

Test: The port is in a test mode.

Current power
consumption

The port’s current power consumption in milliwatts
(mW).

Powered device
class

The PD’s class. See “PD Classes” on page 258 for
details.

Power allocated

The port’s power limit in milliwatts (mW).

Table 26. SHOW POWER-INLINE INTERFACE DETAIL Command

Field

Description