beautypg.com

Show power-inline, Show power-inline command – Allied Telesis AT-8100 Series User Manual

Page 288

background image

Chapter 12: Power Over Ethernet Commands

288

SHOW POWER-INLINE

Syntax

show power-inline

Parameter

None

Mode

Privileged Exec mode

Description

Use this command to display operational information about PoE. An
example is shown in Figure 64. The fields are described in Table 24 on
page 289.

Figure 64. SHOW POWER-INLINE Command

PoE Status:

Nominal Power: 490W

Power Allocated: 346.0W

Actual Power Consumption: 151.0W

Operational Status: On

Power Usage Threshold: 80% (392W)

PoE Interface:

Interface

Admin

Pri

Oper

Power(mW) DeviceClassMax(mW)

port1.0.1

Enabled

Low

Powered

3840

n/a1

4000 [C]

port1.0.2

Enabled

High

Powered

6720

n/a2

7000 [C]

port1.0.3

Enabled

Low

Powered

14784

n/a3

15400 [C]

port1.0.4

Enabled

Crit

Powered

14784

n/a3

15400 [C]

port1.0.5

Enabled

Crit

Powered

3840

n/a1

4000 [C]

port1.0.6

Enabled

High

Powered

6720

n/a2

7000 [C]

port1.0.7EnabledLowPowered14784n/a315400 [C]