beautypg.com

Allied Telesis AT-8100 Series User Manual

Page 430

background image

Chapter 23: Enhanced Stacking

430

3. Use the ESTACK RUN command in the Global Configuration mode to

activate enhanced stacking on the switch. It is not necessary to set the
switch to the member mode because that is the default setting.

4. To save the configuration, enter the WRITE command in the Privileged

Executive mode.

5. Connect port 1 on the new switch to a port on another network device

that is a member of the Network5A VLAN, such as the command
switch.

Now that the replacement member switch is connected to the command
switch through the common VLAN of the enhanced stack, you are ready to
upload the SalesE4.cfg configuration file to it from the command switch
with these steps:

1. Start a local or remote management session on the command switch

of the enhanced stack.

2. Transfer the SalesE4.cfg configuration file from the command switch

to the new member switch by performing these commands:

awplus(config-if)#

end

Return to the Privileged Exec
mode.

awplus# show vlan 12

Verify the new VLAN.

awplus# configure terminal

Enter the Global Configuration
mode.

awplus(config)# estack run

Activate enhanced stacking on the
new switch.

awplus(config)# exit

Return to the Privileged Exec
mode.

awplus# show estack

Confirm the stack mode of the
switch.

awplus# write

Save the configuration.

awplus> enable

Enter the Privileged Executive
mode from the User Executive
mode.

awplus# show estack remotelist

Display the SHOW ESTACK
REMOTELIST command to learn
the stack ID number of the
replacement member switch.