Chapter 6: Temperature and Fan Control Commands

120

Figure 34 shows an example of the information that the command displays
when the switch is a stack master.

Figure 34. SHOW SYSTEM ENVIRONMENT Command

The columns in the display are described here:

Example

The following example displays environmental information for the switch:

Environment Monitoring Status

----------------------------------------------------------------
Switch Model: AT-8100S/24

Stack Member Type: Master

----------------------------------------------------------------
ID Sensor (Units)

Reading

Status

----------------------------------------------------------------

0 PSU 1 On

Normal

1 PSU 2 Off

Off

----------------------------------------------------------------

----------------------------------------------------------------
Switch Model: AT-8100S/16F8-SC

Stack Member Type: Slave 3

----------------------------------------------------------------
ID Sensor (Units) Reading

Status

----------------------------------------------------------------
0 Temp (Degrees C) 37

Normal

1 Fan 1 (RPM) 3467

Normal

2 PSU 1 On

Normal

3 PSU 2 Off

Off

Table 7. SHOW SYSTEM ENVIRONMENT Command

Parameter

Description

Switch Model

Indicates a model name of the switch.

Stack Member Type

Indicates a role of the switch as a stacking
member. This parameter is only
applicable for a stacking member.

ID

Indicates the ID number of an item.

Sensor (Units)

Indicates an item on the switch, such as
temperature, fan, or power supply unit
(PSU).

Reading

Indicates the current reading of the item.

Status