Brocade Mobility Access Point System Reference Guide (Supporting software release 5.5.0.0 and later) User Manual
Page 640
![background image](/manuals/361710/640/background.png)
630
Brocade Mobility Access Point System Reference Guide
53-1003100-01
11
FIGURE 1
Fault Management - Filter Events screen
Use the Filter Events screen to create filters for managing events. Events can be filtered based
on severity, module received, source MAC of the event, device MAC of the event and MAC
address of the wireless client.
2. Define the following Customize Event Filters:
Severity
Set the severity of the event being filtered. Select from the following:
•
All Severities – All events are displayed irrespective of their severity
•
Critical – Only critical events are displayed
•
Error – Only errors are displayed
•
Warning – Only warnings are displayed
•
Informational – Only informational events are displayed
Module
Select the module from which events are tracked. When a single module is
selected, events from other modules are not tracked. Remember this when
interested in events generated by a particular module. Individual modules can
be selected (such as TEST, LOG, FSM etc.) or all modules can be tracked by
selecting All Modules.
Source
Set the MAC address of the source device being tracked. Setting a MAC
address of 00:00:00:00:00:00 allows all devices to be tracked.
Message Substring
Set the error message search string. This filters out any error message or event
message that does not contain the string being searched.