FIGURE 37

SMART RF Recovery Configuration screen - Coverage Hole Recovery tab

25. Set the following Coverage Hole Recovery for 5.0 GHz and 2.4 GHz parameters:

26. Select OK to update the Smart RF Coverage Hole Recovery settings for this policy. Select Reset

to revert to the last saved configuration.

Client Threshold

Use the spinner to set a client threshold from 1 - 255. This is the minimum number of clients a
radio should have associated for coverage hole recovery to trigger. Brocade Mobility 1220 Access
Point, Brocade Mobility 1220 Access PointM, Brocade Mobility 1240 Access Point, and Brocade
Mobility 71XX Access Point model access points can support up to 256 clients per access point or
radio. Brocade Mobility 6511 Access Point can support up to 128 clients per access point or radio.
The default setting is 1.

SNR Threshold

Use the spinner control to set a signal to noise (SNR) threshold (from 1 - 75 dB). This is the SNR
threshold for an associated client as seen by its associated AP radio. When exceeded, the radio
increases its transmit power to increase coverage for the associated client. The default value is 20
dB.

Coverage Interval

Define the interval when coverage hole recovery should be initiated after a coverage hole is
detected. The default is 10 seconds for both 2.4 GHz and 5.0 GHz radios.

Interval

Define the interval coverage hole recovery should be conducted after a coverage hole is detected.
The default is 30 seconds for both 2.4 GHz and 5.0 GHz radios.