Brocade Mobility Access Point System Reference Guide

469

53-1003100-01

6

FIGURE 34

SMART RF - Scanning Configuration screen

NOTE

The monitoring and scanning parameters within the Scanning Configuration screen are only enabled
when Custom is selected as the Sensitivity setting from the Basic Configuration screen.

12. Enable or disable Smart Monitoring Enable by selecting the option. The feature is enabled by

default.

When enabled, detector radios monitor their coverage areas for potential failed peers or
coverage area holes requiring transmission adjustments for coverage compensation.

13. Select this option and specify a threshold number between 10 and 10,000. When this

threshold is reached, awareness settings will be overridden with the values specified.