beautypg.com

2 functions of devices in dvp-plc – Delta Electronics Programmable Logic Controller DVP-PLC User Manual

Page 79

background image

2 Functions of Devices in DVP-PLC

DVP-PLC Application Manual

2-51

Special

M

Function

ES

EX

SS

SA

SX

SC

EH

EH2

SV

Off

Ø

On

STOP

Ø

RUN

RUN

Ø

STO

P

Attribute Latched Default

M1514* Indicating writing to Salve ID#27 is completed

Off

- - R NO

Off

M1515* Indicating writing to Salve ID#28 is completed

Off

- - R NO

Off

M1516* Indicating writing to Salve ID#29 is completed

Off

- - R NO

Off

M1517* Indicating writing to Salve ID#30 is completed

Off

- - R NO

Off

M1518* Indicating writing to Salve ID#31 is completed

Off

- - R NO

Off

M1519* Indicating writing to Salve ID#32 is completed

Off

- - R NO

Off

M1520

EH2/SV: stopping the 3

rd

group pulse output CH2

(Y4, Y5) (Not available in EH)

Off

- - R/W NO

Off

M1521

EH2/SV: stopping the 4

th

group pulse output CH3

(Y6, Y7) (Not available in EH)

Off

- - R/W NO

Off

M1522

EH2/SV: sending out the 3

rd

group pulse output CH2

(Y4, Y5) (Not available in EH)

Off

- Off R

NO

Off

M1523

EH2/SV: sending out the 4

th

group pulse output CH3

(Y6, Y7) (Not available in EH)

Off

- Off R

NO

Off

M1524

EH2/SV: reset after the 3

rd

group pulse output CH2

(Y4, Y5) is completed for PLSY instruction (Not
available in EH)

Off

- - R/W

NO

Off

M1525

EH2/SV: reset after the 4

th

group pulse output CH3

(Y6, Y7) is completed for PLSY instruction (Not
available in EH)

Off

- - R/W

NO

Off

M1526

EH2/SV: reversing Y4 pulse output signal for PWM
instruction (Not available in EH)

Off

- - R/W

NO

Off

M1527

EH2/SV: reversing Y6 pulse output signal for PWM
instruction (Not available in EH)

Off

- - R/W

NO

Off

M1530

EH2/SV: switching time base unit of Y4 output for
PWM instruction

On: 100us; Off: 1ms (Not available in EH)

Off

- - R/W

NO

Off

M1531

EH2/SV: switching time base unit of Y6 output for
PWM instruction

On: 100us; Off: 1ms (Not available in EH)

Off

- - R/W

NO

Off

M1532

EH2/SV: reverse operation of the 3

rd

group pulse

CH2 (Y4, Y5) for PLSV/DPLSV/DRVI/DDRVI/DRVA
/DDRVA instruction (Not available in EH)

Off

- - R/W

NO

Off

M1533

EH2/SV: reverse operation of the 4

th

group pulse

CH3 (Y6, Y7) for PLSV/DPLSV/DRVI/DDRVI/DRVA
/DDRVA instruction

Off

- - R/W

NO

Off

M1534

EH2/SV: CH0 being able to designate deceleration
time. Has to be used with D1348.

Off

- - R/W

NO

Off

M1535

EH2/SV: CH1 being able to designate deceleration
time. Has to be used with D1349.

Off

- - R/W

NO

Off