5 categories & use of application instructions – Delta Electronics Programmable Logic Controller DVP-PLC User Manual
Page 195
![background image](/manuals/75807/195/background.png)
5 Categories & Use of Application Instructions
DVP-PLC Application Manual
5-3
110
–
DECMP
3
Floating Point Compare
3
3
3
- 13
8-23
111
–
DEZCP
3
Floating Point Zone Compare
3
3
3
- 17
8-24
112
-
DMOVR
3
Move Floating Point Data
3
3
3
-
9 8-25
116
- DRAD
3
Angle Æ Radian
-
3
3
- 9 8-26
117
- DDEG
3
Radian Æ Angle
-
3
3
- 9 8-27
118
- DEBCD
3
Float to Scientific Conversion
3
3
3
- 9 8-28
119
-
DEBIN
3
Scientific to Float Conversion
3
3
3
-
9 8-29
120
- DEADD
3
Floating Point Addition
3
3
3
- 13
8-31
121
- DESUB
3
Floating Point Subtraction
3
3
3
- 13
8-32
122
- DEMUL
3
Floating Point Multiplication
3
3
3
- 13
8-33
123
-
DEDIV
3
Floating Point Division
3
3
3
-
13
8-34
124
- DEXP
3
Exponent of Binary Floating Point
3
3
3
- 9 8-35
125
- DLN
3
Natural Logarithm of Binary
Floating Point
3
3
3
- 9 8-36
126
- DLOG
3
Logarithm of Binary Floating Point
3
3
3
- 13
8-37
127
-
DESQR
3
Floating Point Square Root
3
3
3
-
9 8-39
128
- DPOW
3
Floating Point Power Operation
3
3
3
- 13
8-40
129
INT DINT
3
Float to Integer
3
3
3
5
9 8-42
130
-
DSIN
3
Sine
3
3
3
-
9 8-43
131
- DCOS
3
Cosine
3
3
3
- 9 8-45
132
- DTAN
3
Tangent
3
3
3
- 9 8-47
133
- DASIN
3
Arc Sine
-
3
3
- 9 8-49
134
-
DACOS
3
Arc Cosine
-
3
3
-
9 8-50
135
- DATAN
3
Arc Tangent
-
3
3
- 9 8-51
136
- DSINH
3
Hyperbolic Sine
-
-
3
- 9 8-52
137
- DCOSH
3
Hyperbolic Cosine
- - 3
- 9 8-53
Floating Point
Operatio
n
138
-
DTANH
3
Hyperbolic Tangent
-
-
3
-
9 8-54
143
DELAY
-
9
Delay Instruction
-
9
9
3
-
8-55
144
GPWM -
-
General PWM Output
-
9
9
7
- 8-57
145
FTC - -
Fuzzy
Temperature
Control
-
9
9
9
- 8-58
146
CVM
-
-
Valve Control (*)
- - 9
7
- 8-63
147
SWAP DSWAP
3
Byte Swap
3
3
3
3
5 8-66
148
MEMR DMEMR
3
Read File Register
-
3
3
7
13
8-67
149
MEMW DMEMW
3
Write File Register
-
3
3
7
13
8-68
150
MODRW
- -
Read/Write MODBUS Data
3
3
3
11
-
9-1
151
PWD
-
-
Detection of Input Pulse Width
- - 3
5
- 9-10
152
RTMU - -
Start of the Measurement of
Execution Time of I Interruption
- -
3
5
-
9-11
Others
153
RTMD - -
End of the Measurement of the
Execution Time of I Interruption
- -
3
3
-
9-11
154
RAND
-
3
Random Number
-
3
3
7
-
9-13
155
- DABSR -
Read the Absolute Position from a
Servo Motor
-
3
3
7
13
9-14
156
ZRN DZRN - Zero
Return
-
-
3
9
17
9-19
157
PLSV
DPLSV
-
Adjustable Speed Pulse Output
-
-
3
7
13
9-23
158
DRVI DDRVI
-
Drive to Increment
-
-
3
9
17
9-24
Position
Control
159
DRVA DDRVA - Drive
to
Absolute
- -
3
9
17
9-30
160
TCMP
-
3
Time Compare
-
3
3
11
-
9-39
161
TZCP -
3
Time Zone Compare
-
3
3
9
- 9-40
162
TADD -
3
Time Addition
-
3
3
7
- 9-41
163
TSUB -
3
Time Subtraction
-
3
3
7
- 9-42
166
TRD
-
3
Time Read
-
3
3
3
-
9-43
167
TWR -
3
Time Write
-
3
3
3
- 9-45
Real T
im
e
Cale
nda
r
169
HOUR DHOUR
-
Hour Meter
-
3
3
7
13
9-47
170
GRY DGRY
3
BIN Æ Gray Code
-
3
3
5
9 9-49
171
GBIN DGBIN
3
Gray Code Æ BIN
-
3
3
5
9 9-50
Mnemonic
Applicable to
STEPS
Category
A PI
16-bit
32-bit
P
instruction
Function
ES SA
EH 16-bit 32-bit
Page