beautypg.com

2 functions of devices in dvp-plc – Delta Electronics Programmable Logic Controller DVP-PLC User Manual

Page 149

background image

2 Functions of Devices in DVP-PLC

DVP-PLC Application Manual

2-121

M1002

MOV

K17

D1121

H86

D1120

K16

K16

M1351

END

MOV

SET

M1120

MOV

MOV

D1434

D1450

M1350

X1

K16

K16

MOV

MOV

D1435

D1451

Master ID#

COM2 communication protocol

Retain communication protocol

Number of data read from Slave ID#1

Number of data written into Slave ID#1

Number of data read from Slave ID#2

Number of data written into Slave ID#2

Auto mode

Enable EASY PLC LINK

When X1 = On, the data exchange between Master and the two Slaves will be automatically done in

EASY PLC LINK, i.e. the data in D100 ~ D115 in the two Slaves will be read into D1480 ~ D1495 and

D1512 ~ D1527 of the Master, and the data in D1496 ~ D1511 and D1528 ~ D1543 will be written into

D200 ~ D215 of the two Slaves.

Master PLC *1

Slave PLC*2

D1480 ~ D1495

D100 ~ D115 of Slave ID#1

D1496 ~ D1511

D200 ~ D215 of Slave ID#1

D1512 ~ D1527

D100 ~ D115 of Slave ID#2

D1528 ~ D1543









D200 ~ D215 of Slave ID#2

Assume the data in D for data exchange between Master and Slave before EASY PLC LINK is enabled

(M1350 = Off) are as the follow:

Master PLC

Preset value

Slave PLC

Preset value

D1480 ~ D1495

K0

D100 ~ D115 of Slave ID#1

K5,000

D1496 ~ D1511

K1,000

D200 ~ D215 of Slave ID#1

K0

D1512 ~ D1527

K0

D100 ~ D115 of Slave ID#2

K6,000

D1528 ~ D1543

K2,000

D200 ~ D215 of Slave ID#2

K0

After EASY PLC LINK is enabled (M1350 = On), the data in D for data exchange will become:

Write

Read

Read

Write