4 Step Ladder Instructions

DVP-PLC Application Manual

4-11

a) Structure of simultaneous divergence

When the condition at the current step is true, the step can be transferred to many steps. See the diagrams

below. When X0 = On, S20 will be simultaneously transferred to S21, S22, S23 and S24.

Ladder diagram:

X0

SET

SET

S22

S21

S

SET

S23

S20

SET

S24

SFC:

S20

S21

S22

S23

S24

b) Structure of alternative divergence

When the individual condition at the current status is true, the step will be transferred to another individual step.

See the diagrams below. When X0 = On, S20 will be transferred to S30; when X1 = On, S20 will be transferred to

S31; when X2 = On, S20 will be transferred to S32.

Ladder diagram:

X0

SET

SET

S31

S30

S

SET

S32

S20

X1

X2

SFC:

S20

S30

S31

S32

X0

X1

X2

c) Structure of the simultaneous convergence

See the ladder diagram below. A continuous STL instruction represents a simultaneous convergence. When the

condition is true after a continuous output, the step will be transferred to the next step. In the simultaneous

convergence, only when several conditions are true will the transfer be allowed.

Ladder diagram:

X2

SET

S50

S

S40

S

S41

S

S42

SFC:

S40

S50

S41

S42

X2

d) Structure of alternative convergence

See the diagrams below. Depending on the condition of the input signal of which of S30, S40 and S50 becomes

true first, the first one will be first transferred to S60.