2 Functions of Devices in DVP-PLC
DVP-PLC Application Manual
2-110
2.
Special D and special M for ID9 ~ ID16 of the 16 stations in EASY EASY PLC LINK (M1353 = Off) for
SA/SX/SC/EH/EH2/SV:
MASTER PLC
SLAVE ID 9 SLAVE ID 10 SLAVE ID 11 SLAVE ID 12 SLAVE ID 13 SLAVE ID 14 SLAVE ID 15 SLAVE ID 16
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
M1353 = Off: Disable 32 stations in the Link and the function of reading/writing more than 16 data (RST M1353); the
No. of special D for storing the 16 read/written data.
D1736
│
D1751
D1752
│
D1767
D1768
│
D1783
D1784
│
D1799
D1800
│
D1815
D1816
│
D1831
D1832
│
D1847
D1848
│
D1863
D1864
│
D1879
D1880
│
D1895
D1896
│
D1911
D1912
│
D1927
D1928
│
D1943
D1944
│
D1959
D1960
│
D1975
D1976
│
D1991
Number
of data
Number
of data
Number
of data
Number
of data
Number
of data
Number
of data
Number
of data
Number
of data
Number
of data
Number
of data
Number
of data
Number
of data
Number
of data
Number
of data
Number
of data
Number
of data
D144
2
D145
8
D1443 D1459 D1444 D1460 D1445 D1461 D1446 D1462 D1447 D1463 D1448 D1464 D1449 D1465
Start Communication Address
D1363 D1423 D1364 D1424 D1365 D1425 D1366 D1426 D1367 D1427 D1368 D1428 D1369 D1429 D1370 D1430
LINK in SLAVE PLC?
M1368 M1369 M1370 M1371 M1372 M1373 M1374 M1375
Action flag for SLAVE PLC from MASTER PLC
M1384 M1385 M1386 M1387 M1388 M1389 M1390 M1391
“Read/write error” flag
M1400 M1401 M1402 M1403 M1404 M1405 M1406 M1407
“Reading completed” flag (turns “Off” whenever read/write a station is completed)
M1416 M1417 M1418 M1419 M1420 M1421 M1422 M1423
“Writing completed” flag (turns “Off” whenever read/write a station is completed)
M1432 M1433 M1434 M1435 M1436 M1437 M1438 M1439
↓
↓
↓
↓
↓
↓
↓
↓
SLAVE ID 9 SLAVE ID 10 SLAVE ID 11 SLAVE ID 12 SLAVE ID 13 SLAVE ID 14 SLAVE ID 15 SLAVE ID 16
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
Default start communication address D1363 ~ D1370 to be read = H1064 (D100)
Default start communication address D1423 ~ D1430 to be written = H10C8 (D200)