7 Application Instructions API 50-99

D V P - P L C A P P L I C AT I O N M A N U A L

7-39

API Mnemonic

Operands

Function

60

IST

Initial State

Controllers

ES/EX/SS SA/SX/SC EH/SV

Bit Devices

Word Devices

Program Steps

Type

OP

X Y M S K H

KnX KnY KnM KnS T

C

D

E

F

S

*

*

*

D

1

*

D

2

*

IST: 7 steps

PULSE 16-bit 32-bit

ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV

Operands:

S

: Start device in the designated operation mode D

1

:

The smallest No. of designated step in auto mode

D

2

: The biggest No. of designated step in auto mode

Explanations:

1. S will occupy 8 consecutive points.

2. Range

of

D

1

and D

2

: for SA/SX/SC/EH/EH2/SV S20 ~ S899; for ES/EX/SS S20 ~ S127; D

2

> D

1

.

3. See the specifications of each model for their range of use.

4. ES/SA series MPU does not support E, F index register modification.

5. IST instruction can only be used once in the program.

6. Flags: M1040 ~ M1047. See remarks for more details.

7. IST instruction is a handy instruction specifically for the initial status of step ladder control procedure to

accommodate special auxiliary relay.

Program Example 1:

1. Use of IST instruction

M1000

IST

X10

S20

S60

S

X10: Individual operation

X11: Zero return
X12: Step operation
X13: One cycle operation

X14: Continuous operation
X15: Zero return enabled switch
X16: Start switch
X17: Stop switch

2. When IST instruction is being executed, the following special auxiliary relays will switch automatically.

M1040: Operation forbidden
M1041: Operation starts
M1042: Pulse output enabled
M1047: STL monitor enabled

S0: Initiates manual operation
S1: Initiates zero return
S2: Initiates auto operation

3. S10 ~ S19 are for zero return and cannot be used as general steps. When S0 ~ S9 are in use, S0 ~ S2 represent

manual operation mode, zero return mode and auto operation mode. Therefore, in the program , you have to

write the circuit of the three steps in advance.

4. When switched to S1 (zero return) mode, any On in S10 ~ S19 will result in no zero return.

5. When switched to S2 (auto operation) mode, any On of the S in D

1

~ D

2

or M1043 = On will result in no auto

operation.