2 Functions of Devices in DVP-PLC

DVP-PLC Application Manual

2-34

Special

M

Function

ES

EX

SS

SA

SX

SC

EH

EH2

SV

Off

Ø

On

STOP

Ø

RUN

RUN

Ø

STO

P

Attribute Latched Default

M1007*

Data do not exist in the program area of data backup
memory card

Off

- - R NO Off

M1008* Scanning watchdog timer (WDT) On

Off

Off

- R NO

Off

M1009

Insufficient 24V DC supply, LV signal has been
occurred.

Off

- - R NO Off

M1010

ES/SA: PLSY Y0 mode selection, continuous output
when On

EH/EH2/SV: Pulse output when reaching END
instruction

Off

- - R/W NO Off

M1011* 10ms clock pulse, 5ms On/5ms Off

Off

- - R NO Off

M1012* 100ms clock pulse, 50ms On / 50ms Off

Off

- - R NO Off

M1013* 1s clock pulse, 0.5s On / 0.5s Off

Off

- - R NO Off

M1014* 1min clock pulse, 30s On / 30s Off

Off

- - R NO Off

M1015* Enabling high-speed counter

Off

- - R/W NO Off

M1016* Displaying real time clock in A.D.

Off

- - R/W NO Off

M1017* ±30 seconds correction on real time clock

Off

- - R/W NO Off

M1018

Flag for radian/degree, On: for degree

Off

- - R/W NO Off

M1019

Enabling frequency measurement card

Off

Off

- R NO

Off

M1020 Zero

flag

Off

- - R NO Off

M1021 Borrow

flag

Off

- - R NO Off

M1022 Carry

flag

Off

- - R NO Off

M1023

PLSY Y1 mode selection, continuous output when
On

Off

- - R/W NO Off

M1024

Requesting COM1 monitoring

Off

- - R NO Off

M1025

There is incorrect request for communication.

Off

- - R NO Off

M1026

Enabling RAMP module

Off

- - R/W NO Off

M1027

Number of PR outputs

Off

- - R/W NO Off

M1028

10ms time switching flag.

Off: time base of T64 ~ T126 = 100ms

On: time base of T64 ~ T126 = 10ms

Off

- - R/W NO Off

M1029*

ES/SA: Y0 pulse output of PLSY, PLSR instructions
is completed, or other relevant instructions complete
their executions.

EH/EH2/SV: the 1

st

group pulse output CH0 (Y0, Y1)

is completed, or other relevant instructions complete
their executions.

Off

- - R NO Off