2 Functions of Devices in DVP-PLC

DVP-PLC Application Manual

2-101

Settings of acceleration/deceleration time, frequency and number of pulses:

Started No. D

+ index value

Setting

+0 2

+2 250

(Hz)

+3 100

(ms)

+4 500

(Hz)

+5 10,000

(Hz)

+6, +7

10 (pulses)

+8 9,750

(Hz)

+9 50

(ms)

+10 -500

(Hz)

+11 250

(Hz)

+12, +13

30,000 (pulses)

The program: (Assume X7 is the switch for triggering zero return)

X7

SET

END

SET

X0

RST

X0

SET

RST

Program explanations:

a) When X7 is triggered, M1144 will enable an acceleration. Set M1149 (counting temporarily stops) and 10

pulses will be sent out before the deceleration switch X0 is triggered and the program will enter the

deceleration section.

b) When X0 is disabled (i.e. zero return is completed), set M1148 to disable this function.

Note: The example offered here is one of the applications. Please adjust the settings of the parameters according to

the features of and restrictions on your machines.

Function Group

Single Step Execution

Number

M1170, M1171, D1170

Contents:

1. Special D and special M for single step execution for EH/EH2/SV: