beautypg.com

Delta Electronics Programmable Logic Controller DVP-PLC User Manual

Page 234

background image

6 Application Instructions API 00-49

DVP-PLC Application Manual

6-22

Program Example 2:

When M1168 = On (in BIN mode) and SMOV instruction is in use, D10 and D20 will not be converted in BCD format

but be moved in BIN format (4 digits as a unit).

Unchanged

Unchanged

D10(BIN 16 bits)

D20(BIN 16 bits)

Moving digits

M1000

X0

Digit 4

Digit 3

Digit 2

Digit 1

Digit 4

Digit 3

Digit 2

Digit 1

M1168

SMOV

D10

K2

D20

K3

K4

Before the execution, assume D10 = H1234 and D20 = H5678. After the execution, D10 will remain unchanged and

D20 will become H5128.

Program Example 3:

1.

This instruction can be used to combine the DIP switches connected to the input terminals with interrupted No.

2.

Move the 2

nd

right digit of the DIP switch to the 2

nd

right digit of D2, and the 1

st

left digit of the DIP switch to the

1

st

right digit of D1.

3.

Use SMOV instruction to move the 1

st

digit of D1 to the 3

rd

digit of D2 and combine the two DIP switches into

one.

10

1

10

0

10

2

6

4

2

PLC

X13~X10

X27~X20

8

8

8

M1000

BIN

K2X20

D2

D1

SMOV

D1

K1

D2

K3

K1

K1X10

(X20~X27)BCD

(X10~X13)BCD

2 digits

D2(BIN)

1 digit

D1(BIN)

M1001

M1168

BIN