9 Application Instructions API 150-199

DVP-PLC Application Manual

9-46

4.

Whenever X11 = On, RTC will perform a ±30 second correction. The correction is performed according to the

rules: When the second hand of RTC locates at 1 ~ 29, the second will be automatically reset to “0” and the

minute hand will remain at its location. When the second hand locates at 30 ~ 59, the second will be

automatically reset to “0” and the minute hand will increase by 1 minute.

X10

MOV

K03

D0

MOV

K2

D1

MOV

K8

D2

MOV

K19

D3

MOV

K15

D4

MOV

K27

D5

MOV

K30

D6

TWR

D0

M1017

X11

Year (2003)

Day (Tuesday)

Month (August)

Date

Hour

Minute

Second

Write the set time into RTC

30 seconds correction