beautypg.com

2 functions of devices in dvp-plc – Delta Electronics Programmable Logic Controller DVP-PLC User Manual

Page 118

background image

2 Functions of Devices in DVP-PLC

DVP-PLC Application Manual

2-90

(0,0)

X

Y

(50,000, 50,000)

10 sections

(Figure 3)

Axis Section

Device D

Output frequency

Device D

Number of output pulses

1

D201, D200

K1,230

D203, D202

K615

2

D205, D204

K3,664

D207, D206

K1,832

3

D209, D208

K6,004

D211, D210

K3,002

4

D213, D212

K8,200

D215, D214

K4,100

5

D217, D216

K10,190

D219, D218

K5,095

6

D221, D220

K11,932

D223, D222

K5,966

7

D225, D224

K13,380

D227, D226

K6,690

8

D229, D228

K14,498

D231, D230

K7,249

9

D233, D232

K15,258

D235, D234

K7,629

X

10

D237, D236

K15,644

D239, D238

K7,822

1

D301, D300

K15,644

D303, D302

K7,822

2

D305, D304

K15,258

D307, D306

K7,629

3

D309, D308

K14,498

D311, D310

K7,249

4

D313, D312

K13,380

D315, D314

K6,690

5

D317, D316

K11,932

D319, D318

K5,966

6

D321, D320

K10,190

D323, D322

K5,095

7

D325, D324

K8,200

D327, D326

K4,100

8

D329, D328

K6,004

D331, D330

K3,002

9

D333, D332

K3,664

D335, D334

K1,832

Y

10 D337,D336 K1,230 D339,

D338

K615

(Table 2)

c)

Draw arcs in the four quadrants

Destination: Draw four 90° arcs (see figure 4)

Program explanation: When the direction signal is On, the direction will be a positive one; when the

direction signal is Off, the direction will be a negative one (see figure 5)

Output frequency and number of pulses: see table 2