beautypg.com

Delta Electronics Programmable Logic Controller DVP-PLC User Manual

Page 384

background image

7 Application Instructions API 50-99

D V P - P L C A P P L I C AT I O N M A N U A L

7-100

3. When

n

= 2, the bit structure will be as:

0

1

0

0

0

0

1

0

0

0

0

1

1

1

D20

D21

D10

1

1

0

0

1

0

0

0

0

0

0

0

0

0

0

0

1

1

43H

C

44H

D

C

D

4. When

n

= 1 ~ 16:

D
n

D13 D12 D11 D10

1

***C

H

2 **CD

H

3 *CDE

H

4

CDEF H

5

***C H

DEF8 H

6

**CD H

EF89 H

7 *CDE

H

F89A

H

8

CDEF H

89AB H

9

***C H

DEF8 H

9AB4 H

10

**CD H

EF89 H

AB45 H

11

*CDE H

F89A H

B456 H

12

The used
registers
which are not
specified are
all 0

CDEF H

89AB H

4567 H

13

***C H

DEF8 H

9AB4 H

5670 H

14

**CD H

EF89 H

AB45 H

6701 H

15

*CDE H

F89A H

B456 H

7012 H

16

CDEF H

89AB H

4567 H

0123 H