2 Functions of Devices in DVP-PLC

DVP-PLC Application Manual

2-87

No.

Function

M1133

Output switch for special high-speed pulse Y0 (50KHz) (On = enabled)

M1134

On = Continuous output switch for special high-speed pulse Y0 (50KHz)

M1135

“Number of pulses reached” flag for special high-speed pulse Y0 (50KHz)

D1133

Start No. of control register (D) for special high-speed pulse Y0 (50KHz)

2.

Parameters for D1133:

Index

Function

+ 0

The lower 16 bits of the 32 bits for output frequency of special high-speed pulse Y0

+ 1

The higher 16 bits of the 32 bits for output frequency of special high-speed pulse Y0

+ 2

The lower 16 bits of the 32 bits for number of output pulses of special high-speed pulse Y0

+ 3

The higher 16 bits of the 32 bits for number of output pulses of special high-speed pulse Y0

+ 4

The lower 16 bits of the 32 bits of the present number of special high-speed pulses Y0

+ 5

The higher 16 bits of the 32 bits of the present number of special high-speed pulses Y0

3. The

function:

All output frequency and number of pulses stated in the table above can be modified when M1133 = On and

M1135 = On. The modification will not affect the present output pulses. The present number of output pulses is

updated in every scan time. When M1133 turns from “Off” to “on”, the number will be cleared as “0”. When 1133

turns from “On” to “Off”, the last numner of output pulses will be shown.

Note:

The special high-speed pulse output function can only be used on specific Y0 output point when PLC is in RUN status.

It can coexist with PLSY (Y0) in the program and PLSY (Y1) will not be affected. If PLSY (Y0) instruction is executed

prior to this function, the function cannot be used and vice versa. When the function is executed, the general function,

general Y0 output will be invalid but Y1 ~ Y7 can be used.

The output frequency of this function is higher (max. 50KHz) than that of PLSY instruction.

Function Group

2-axis Synchronous Control (PH)

Number

M1133, M1135, D1133 ~ D1136

Contents:

1.

Special D and special M for 2-axis synchronous drawing oblique and arc for SC_V1.4 and versions above:

Device No.

Function

M1133

Start flag for Y10 output for two-axis synchronous control

M1135

Start flag for Y11 output for two-axis synchronous control

D1133

Start No. of control register (D) for Y10 output for two-axis synchronous control

D1134

Number of sections for Y10 output for two-axis synchronous control

D1135

Start No. of control register (D) for Y11 output for two-axis synchronous control

D1136

Number of sections for Y11 output for two-axis synchronous control

2.

Parameters for D1133, D1135: