10 Application Instructions API 200-249

DVP-PLC Application Manual

10-6

D

S

1

0

=F500

=F30

=F500

Destination value

Source value

Remarks:

1. Range

of

S

1

for 16-bit instruction: max. source value ≥ S

1

≥ min. source value; -32,768 ~ 32,767. If the value falls

without the bounds, the bound value will be used for calculation.

2. Range of integer S

1

for 32-bit instruction: max. source value ≥ S

1

≥ min. source value; -2,147,483,648 ~

2,147,483,647. If the value falls without the bounds, the bound value will be used for calculation.

3. Range of floating point S

1

for 32-bit instruction: max. source value ≥ S

1

≥ min. source value; following the range of

32-bit floating point. If the value falls without the bounds, the bound value will be used for calculation.

4. Please be aware that the max. source value must > min. source value, but it is not necessary that max.

destination value > min. destination value.

5. Only ES_V6.2, SA/SX_V1.6, SC_V1.4, EH2/SV_V1.0 and versions above support this instruction. EH series

MPU does not support this instruction.