9 Application Instructions API 150-199
DVP-PLC Application Manual
9-77
7.
When the 2-axis synchronous motion instruction is enabled, the start frequency and acceleration/deceleration
time in Y axis will be same as the settings in X axis.
8.
The number of output pulses for the 2-axis motion shall not be less than 59; otherwise the line drawn will not be
straight enough.
9.
There is no limitation on the number of times using the instruction. However, assume CH1 or CH2 output is in
use, the 1
st
group X/Y axis will not be able to output. If CH3 or CH4 output is in use, the 2
nd
group X/Y axis will
not be able to output.
Program Example:
1. Draw a rhombus as the figure below.
(0, 0)
(-2700 0,-27 000)
(0, -5 5000)
(270 00,-27 000)
X
Y
2. Steps:
a) Set the four coordinates (0,0), (-27000, -27000), (0, -55000), (27000, -27000) (as the figure above). Calculate the
relative coordinates of the four points and obtain (-27000, -27000), (27000, -28000), (27000, 27000), and (-27000,
27000). Place them in the 32-bit (D200, D202), (D204, D206), (D208, D210), (D212, D214).
b) Write program codes as follows.
c) PLC RUN. Set M0 as On and start the 2-axis line drawing.
D214
M1029
DPPMR
END
D210
DPPMR
D206
DPPMR
K100000
D202
DPPMR
Y0
= D0 K1
= D0 K2
= D0 K4
M0
K1
D0
D0
M0
M1029
K100000
Y0
K100000
Y0
K100000
Y0
3. Motion
explanation:
When PLC RUN and M0 = On, PLC will start the first point-to-point motion by 100KHz. D0 will plus 1 whenever a
point-to-point motion is completed and the second point-to-point motion will start to execute automatically. The
same motion will keep executing until the fourth point-to-point motion is completed.