2 Functions of Devices in DVP-PLC

DVP-PLC Application Manual

2-42

Special

M

Function

ES

EX

SS

SA

SX

SC

EH

EH2

SV

Off

Ø

On

STOP

Ø

RUN

RUN

Ø

STO

P

Attribute Latched Default

M1234

Counting mode of C234 (On: counting down)

Off

- - R/W NO Off

M1235

Counting mode of C235 (On: counting down)

Off

- - R/W NO Off

M1236

Counting mode of C236 (On: counting down)

Off

- - R/W NO Off

M1237

Counting mode of C237 (On: counting down)

Off

- - R/W NO Off

M1238

Counting mode of C238 (On: counting down)

Off

- - R/W NO Off

M1239

Counting mode of C239 (On: counting down)

Off

- - R/W NO Off

M1240

Counting mode of C240 (On: counting down)

Off

- - R/W NO Off

M1241

Counting mode of C241 (On: counting down)

Off

- - R/W NO Off

M1242

Counting mode of C242 (On: counting down)

Off

- - R/W NO Off

M1243

Counting mode of C243 (On: counting down)

Off

- - R/W NO Off

M1244

Counting mode of C244 (On: counting down)

Off

- - R/W NO Off

M1245

Counting mode of C245 (On: counting down)

Off

- - R/W NO Off

M1246

C246 counter monitoring (On: counting down)

Off

- - R NO Off

M1247

C247 counter monitoring (On: counting down)

Off

- - R NO Off

M1248

C248 counter monitoring (On: counting down)

Off

- - R NO Off

M1249

C249 counter monitoring (On: counting down)

Off

- - R NO Off

M1250

C250 counter monitoring (On: counting down)

Off

- - R NO Off

M1251

C251 counter monitoring (On: counting down)

Off

- - R NO Off

M1252

C252 counter monitoring (On: counting down)

Off

- - R NO Off

M1253

C253 counter monitoring (On: counting down)

Off

- - R NO Off

M1254

C254 counter monitoring (On: counting down)

Off

- - R NO Off

M1255

C255 counter monitoring (On: counting down)

Off

- - R NO Off

M1258

Y0 pulse output signal reversing for PWM instruction

Off

- - R/W NO Off

M1259

Y2 pulse output signal reversing for PWM instruction

Off

- - R/W NO Off

M1260

X5 as the reset input signal for all high-speed
counters

Off

- - R/W NO Off

M1261

High-speed comparator comparison flag for DHSCR
instruction

Off

- - R/W NO Off

M1264

Enabling reset function of HHSC0

Off

- - R/W NO Off

M1265

Enabling start function of HHSC0

Off

- - R/W NO Off

M1266

Enabling reset function of HHSC1

Off

- - R/W NO Off

M1267

Enabling start function of HHSC1

Off

- - R/W NO Off

M1268

Enabling reset function of HHSC2

Off

- - R/W NO Off

M1269

Enabling start function of HHSC2

Off

- - R/W NO Off