9 Application Instructions API 150-199
DVP-PLC Application Manual
9-101
D1336:
Low word of the current number of output pulses of CH0
D1337:
High word of the current number of output pulses of CH0
D1338:
Low word of the current number of output pulses of CH1
D1339:
High word of the current number of output pulses of CH1
D1375:
Low word of the current number of output pulses of CH2
D1376:
High word of the current number of output pulses of CH2
D1377:
Low word of the current number of output pulses of CH3
D1378:
High word of the current number of output pulses of CH3
D1340:
Start/end frequency settings of CH0 (default: K200)
D1352:
Start/end frequency settings of CH1 (default: K200)
D1379:
Start/end frequency settings of CH2 (default: K200)
D1380:
Start/end frequency settings of CH3 (default: K200)
D1348:
Deceleration time of CH0 pulse output when M1534 = On (default: K100)
D1349:
Deceleration time of CH1 pulse output when M1535 = On (default: K100)
D1350:
Deceleration time of CH2 pulse output when M1536 = On (default: K100)
D1351:
Deceleration time of CH3 pulse output when M1537 = On (default: K100)
D1343:
Acceleration/deceleration time of CH0 pulse output (default: K100)
D1353:
Acceleration/deceleration time of CH1 pulse output (default: K100)
D1381:
Acceleration/deceleration time of CH2 pulse output (default: K100)
D1382:
Acceleration/deceleration time of CH3 pulse output (default: K100)