9 Application Instructions API 150-199

DVP-PLC Application Manual

9-13

API Mnemonic

Operands

Function

154

RAND P

Random Number

Controllers

ES/EX/SS SA/SX/SC EH/SV

Bit Devices

Word Devices

Program Steps

Type

OP

X Y M S K H

KnX KnY KnM KnS T

C

D

E

F

S

1

*

*

*

*

*

*

*

*

*

*

*

S

2

*

*

*

*

*

*

*

*

*

*

*

D

*

*

*

*

*

*

*

*

RAND, RANDP: 7 steps

PULSE 16-bit 32-bit

ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV

Operands:

S

1

: Lower bound of the random number S

2

: Upper bound of the random number D: The random number

produced

Explanations:

1.

S

1

S

2

; K0 ≦ S

1

, S

2

≦K32,767

2.

See the specifications of each model for their range of use.

3. Entering

S

1

> S

2

will result in operation error. The instruction will not be executed at this time, M1067, M1068 =

On and D1067 records the error code 0E1A (hex).

Program Example:

When X10 = On, RAND will produce the random number between the lower bound D0 and upper bound D10 and

store the result in D20.

X10

RAND

D0

D10

D20