Interfacing With External Devices (Device Interface Menu)
(Rising Edge):
The trigger causes the relay contacts to be open-
circuit or drives the output high, and holds this state for the
specified pulse width.
(Falling Edge):
The trigger causes the relay contacts to be shorted
or drives the output low, and holds this state for the specified
pulse width.
(Any Edge):
Each time the trigger occurs, the relay contacts are
alternately closed or opened, or the output is switched between
high and low.
Status:
Depending on the status, the relay contacts are closed or opened,
or the output is switched between high and low.
No Operation:
The trigger has no effect on the relay state or output level.
4
Turning the knobs, select the pulse width and timing to be set.
a) 1: Field 1, 2: Field 2, 3: Any
When “
” is selected as the trigger polarity, there is no Pulse Width
setting. When “Status” is selected, there is no Pulse Width or Timing
setting.
5
In the
M/E-1 to M/E-3 and P/P:
Set an action for the M/E or PGM/PST bank.
Common:
Set an action for error status.
6
Using any of the following methods, select the action to be set.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs.
a)
•
Action list when the trigger type is other than “Status”
When Source is M/E-1, M/E-2, or M/E-3: Key1 SS ? Recall, Key2 SS ? Recall, Key3
SS ? Recall, Key4 SS ? Recall, No Action
When Source is P/P: DSK1 SS ? Recall, DSK2 SS ? Recall, DSK3 SS ? Recall, DSK
4 SS ? Recall, No Action
When Source is Common: KF Run, No Action
•
Action list when the trigger type is “Status”
Knob
Parameter
Adjustment
Setting values
3
Pulse Width
Pulse width
1 to 60 (fields)
4
Timing
Output timing
1 to 3
a)
Knob
Parameter
Adjustment
Setting values
2
Action
Action selection
1 and upwards
a)
5
Reg No
Register number
1 to 4
b)