Sony Multi Interface Shoe Adapter User Manual
Page 1050
Cha
1050
Setting Status of the MKS-8080/8082 in Simple Connection
Setting Status of the MKS-8080/8082 in
Simple Connection
As a result of making the simple connection, the MKS-8080/8082 operates in
AUX bus mode, and the settings are the following factory defaults.
With regard to the meaning of the following settings, see the section “Menu
Operations” in the Operation Manual for the MKS-8080/8082.
C: SET SWITCHER ID (for AUX mode)
This is set to 001, which is the station number of the CCP-9000/9000A.
D: SET AUX DESTINATION/SOURCE (for AUX mode)
The source is set to IN001 and following, and destination is set to OUT001 and
following.
H: SET PHANTOM TABLE (for Router mode)
This is unset, since the unit does not operate in router mode.
N: SET PANEL TABLE (for Router mode)
The source is set to IN001 and following, and destination is set to OUT001 and
following. However, since the unit does not operate in router mode, these
settings are not used.
R: SET ROUTE
Since when using the simple connection the switcher and router cannot be
connected in cascade, no route setting is required, and this is unset.
O: SET AVAILABLE SOURCE/DESTINATION
Set the source and destination ranges so that the MVS-6000 inputs and outputs
can be selected.
Y: SET DISPLAY MODES
The DISPLAY MODES/PANEL FUNCTION setting is set to NORMAL. The
TALLY GROUP setting is set to be the same as the setting in Engineering
Setup >Router/Tally >Tally Group on the MVS-6000.
Z: SET PANEL STATUS
The various settings are the same as the factory default settings.