beautypg.com

Sony Multi Interface Shoe Adapter User Manual

Page 88

background image

88

Basic Menu Operations

Ch
apt

er 2

Me

nu
s

an
d Cont

rol P

ane

l

Setting parameters

This marking on a function button indicates
that there are parameters which can be
adjusted with the knobs.
Pressing this function button assigns
parameters to the knobs.

You can set the parameter values by either
of the following methods.
• Turn the knob (1 to 5) corresponding to

the parameter, to adjust the value.

• Press the knob parameter buttons (1 to 5)

corresponding to the parameter. This
displays the numeric keypad window
allowing you to enter the desired value.

In the description of specific setting
procedures, the knob adjustment is
described, as follows.

Example:

When wipe pattern key is selected

When the [MENU] button in the device
control block is lit, you can use the trackball
and Z-ring to control the parameters.
• Move the trackball on the x-axis to

control the parameter for knob 1 or on the
y-axis to control the parameter for knob
2. Moving up or to the right increases the
parameter value, and moving down or to
the left decreases the parameter value.

• Use the Z-ring to adjust the parameter for

knob 3. Turning clockwise increases the
parameter value, and turning
counterclockwise decreases the
parameter value.

Going back to the previous menu

To return to the last displayed menu, press
the previous page button.

Returning to default state in function
groupings

1

Press the [Default Recall] button,
turning it on.

This enters the menu default recall
mode.

2

Press the VF button you want to return
to the default state.

This returns the settings within the
function grouping to the default state,
and the [Default Recall] button goes
off.

Note

The default state of the settings depends on
the setting of the initial status mode, set in
the Setup menu of system setup, as follows.

User:

The state when [Initial Status Define]

is executed.

Factory:

Factory default settings

Returning knob parameters to
default state

1

Press the [Default Recall] button,
turning it on.

This enters the menu default recall
mode.

Knob

Parameter

Adjustment

Setting values

1

Size

Pattern size

0.00 to 100.00

2

Soft

Edge softness

0.00 to 100.00

3

Density

Key density

0.00 to 100.00