beautypg.com

Gpi output setting (gpi output assign menu), Making dcu gpi output settings, Gpi output setting (gpi output assign menu) 5 – Sony Multi Interface Shoe Adapter User Manual

Page 1015: Making dcu gpi output settings 5

background image

1015

GPI Output Setting (GPI Output Assign Menu)

Chapt

er

22

DCU

Se

tu

p (DCU)

GPI Output Setting (GPI Output Assign
Menu)

To set the trigger type and so on for each GPI output, display the DCU >GPI
Output Assign menu.

To display the GPI Output Assign menu

In the Engineering Setup menu, select VF5 ‘DCU’ and HF4 ‘GPI Output
Assign.’
The GPI output port setting status appears in the status area.

Making DCU GPI Output Settings

1

In the DCU >GPI Output Assign menu, using any of the following
methods select what the setting applies to.

• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.

2

In the group, select the trigger polarity.

(Rising Edge):

The trigger causes the relay contacts to be open-

circuit or drives the output high, and holds this state for the
specified pulse width.

(Falling Edge):

The trigger causes the relay contacts to be shorted

or drives the output low, and holds this state for the specified
pulse width.

(Any Edge):

Each time the trigger occurs, the relay contacts are

alternately closed or opened, or the output is switched between
high and low.

Status:

Depending on the status, the relay contacts are closed or opened,

or the output is switched between high and low.

No Operation:

The trigger has no effect on the relay state or output level.

3

Turning the knobs, select the pulse width and timing to be set.

Knob

Parameter

Adjustment

Setting values

1

No

GPI output

1 to 50