DME Special Effect Operations

4

In the group, select the interpolation method for
the key signal.

Adaptive:

Detect changes in the luminance component of the key signal

separately, and switch automatically between fields and frames.

Field:

Do interpolation in field units. This gives natural movement,

suitable for moving video.

Frame:

Do interpolation in frame units. This gives higher image precision,

suitable for still pictures.

5

When you select Adaptive in step

4

, set the following parameter.

6

In the group, set the number of pixels to use in
interpolation.

Multi:

Use multi-point interpolation. This gives higher picture quality.

Linear:

Use two-point interpolation.

7

In the group, select the method used to show the picture
reduced or expanded.

Mode1 (standard):

Even when the picture is reduced, add compensation

so that it can be seen clearly.

Mode2 (soft):

Suppress aliasing when expanding or reducing the picture.

Mode3 (sharp):

Do not surpress aliasing when expanding or reducing the

picture.

Applying the anti-moire filter

You can reduce the moire patterns created by interpolation when an image is
enlarged, compressed, or rotated.

Note

This function is effective only when the HD signal format is used on the MVE-
8000A and MKS-6470.

1

In the DME menu, select VF6 ‘Input/Output’ and HF3 ‘Process.’

The Process menu appears.

2

Press [Anti Moire Filter], turning it on.

Knob

Parameter

Adjustment

Setting values

1

Mode

Degree of motion detection