Setting the source signal name – Sony Multi Interface Shoe Adapter User Manual
Page 906

Ch
apt
906
Cross-Point Settings (Xpt Assign Menu)
Hold:
Acts as a shift button, and the shifted version of the cross-point buttons
is enabled while the button is held down.
Lock:
Acts as a shift button, and pressing the button toggles between the
shifted version and the unshifted version.
Off:
Acts as a cross-point button, in a 16-button system as button number 16,
in a 24-button system as button number 24, and in a 32-button system as
button number 32.
Setting the action of the [SHIFT] button in the cross-point control
block
In the
Assign menu or Panel >Xpt Assign >Table Button Assign menu, select either
of the following.
Display:
Functions as a shift button dedicated to the source name displays.
Shift All Bus:
Functions as a shift button for all buses.
Notes
• It is not possible to make this setting separately for each of the M/E and
PGM/PST banks.
• “Shift All Bus” is only valid when the cross-point button shift operation
(see
previous item)
is set to “Lock” or “Off.”
Setting the source signal name
1
In the Panel >Xpt Assign menu or Panel >Xpt Assign >Table Button
Assign menu, press [Src Name/LCD Color].
The Src Name/LCD Color menu appears.
2
Turn the knob to select the signal to be set.
3
Press [Source Name].
A keyboard window appears.
4
Enter any name of not more than 16 characters, then press [Enter].
For details of keyboard window operation, see “Menu Operations” in
Chapter 2 (Volume 1).
Knob
Parameter
Adjustment
Setting values
1
Source No
Source signal selection
1 to 128
2
Num
Number of source signals to be
selected
1 to 128