Inhibiting utility bus and key operations – Sony Multi Interface Shoe Adapter User Manual
Page 899
899
Overall Control Panel Settings (Config Menu)
Chap
To cancel an assignment
Select the button, then press [Clear].
This removes the assignment to that button.
To return all device selection button assignments to the factory
default state
In the Joystick/Trackball Module menu, press [Default].
Inhibiting Utility Bus and Key Operations
You can inhibit operations on the utility bus and keys 1 to 4 of the M/E and
PGM/PST banks by menu operations.
This inhibitions apply for the following control blocks.
• Cross-point control block
• Transition control block
• Independent key transition control block
1)
1) Only when the Key1, 2 or Key 3, 4 are assigned by the Compact Key Module Assign menu.
Note
This operation cannot be done in the CCP-9000/9000A.
1
In the Panel >Config menu, press [M/E Operation Inhibit].
M/E Operation Inhibit menu appears.
2
In the list in the status area, using any of the following methods, select the
switcher bank for which operations are to be inhibited.
• Press directly on the desired switcher bank in the list.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
3
In the
([Util2 Bus] or [Key1] to [Key4]) for which operations are to be inhibited.
Knob
Parameter
Adjustment
Setting values
1
Bank
Switcher bank selection for
inhibiting operations
1 to 4