Serial Port Settings (Serial Port Assign Menu)

Chapt

er

22

DCU

Se

tu

p (DCU)

6. Extended VTR (Abekas A53 protocol)
7. Mixer ESAM-II

Note

Mixer ESAM-II cannot be operated from this system. It can only be
operated from an editing keyboard.

4

Press [Device Type Set].

The selected protocol is reflected on the left of the status area.

5

To enter the name of the serial port, press [Set] in the group.

A keyboard window appears. You can enter a name of not more than 16
characters.
If no name is set for the serial port, it is displayed as “DCUd_PORTs-p.”

d:

1 or 2 (DCU No.)

s:

2 to 6 (Slot No.)

p:

1 to 6 (Port No.)

6

Press [Enter].

To return the set name to the default name

Press [Clear] in the group.

7

From the group, select the control panel (SCU1, SCU2 or
SCU3) assigned to operations on the external device connected to the
serial port.

Deleting the serial port assignment

1

In the DCU >Serial Port Assign menu, select the target for the setting
(DCU1 or DCU2) from the group.

2

Using any of the following methods, specify the serial port.

• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.

a) The range of setting values depends on the DCU port setting. (When the MKS-2700 is

connected, select 2 for the slot and a value in the range 1 to 6 for the port.)

3

Press [Clear].

Knob Parameter

Adjustment

Setting

values

1

Port No

Serial port

1 and upwards

a)