01.98

TNC 407/TNC 415/TNC 425

11 PLC inputs/outputs

3-61

11.4 Connector assignment on the PA 110

Power supply see section "PLC power supply"

X2,X3,X4,X5 analogue inputs
Assignment as X15,X16,X17,X18 on PL 410

X7,X8,X9,X10 connection for Pt 100
Assignment as X19,X20,X21,X22 on PL 410

11.5 Connecting cable

Please use only HEIDENHAIN connecting cables.

11.5.1 Connection of PLC inputs/outputs on the LE

HEIDENHAIN recommends the installation of a transfer unit with a terminal strip in the switch
cabinet.

max. 40 m

Id.-Nr. 263 954 ..

If a transfer unit is not required, use HEIDENHAIN connecting cable Id.-Nr. 244 005 ..

Assignment:

1

= green/red

14 = green/blue

27 = yellow/black

2

= brown/black 15 = yellow

28 = white/yellow

3

= white/black

16 = red

29 = grey/blue

4

= green/black

17 = grey

30 = pink/blue

5

= brown/red

18 = blue

31 = pink/red

6

= white/red

19 = pink

32 = brown/blue

7

= white/green

20 = white/grey

33 = pink/green

8

= red/blue

21 = yellow/grey

34 = brown

9

= yellow/red

22 = green/red

35 = yellow/pink

10 = grey/pink

23 = white/pink

36 = violet

11 = black

24 = grey/green

37 = white

12 = pink/brown

25 = yellow/brown

13 = yellow/blue

26 = grey/brown

max. 25 m

Id.-Nr. 244 005..

If the connector is to be mounted at the customer's facility, HEIDENHAIN can provide a 37-pin
solderable connector (Id.-Nr. 243 937 ZY).