11.4 Connector assignment on the PA 110
Power supply see section "PLC power supply"
X2,X3,X4,X5 analogue inputs
Assignment as X15,X16,X17,X18 on PL 410
X7,X8,X9,X10 connection for Pt 100
Assignment as X19,X20,X21,X22 on PL 410
11.5 Connecting cable
Please use only HEIDENHAIN connecting cables.
11.5.1 Connection of PLC inputs/outputs on the LE
HEIDENHAIN recommends the installation of a transfer unit with a terminal strip in the switch
cabinet.
max. 40 m
Id.-Nr. 263 954 ..
If a transfer unit is not required, use HEIDENHAIN connecting cable Id.-Nr. 244 005 ..
Assignment:
1
= green/red
14 = green/blue
27 = yellow/black
2
= brown/black 15 = yellow
28 = white/yellow
3
= white/black
16 = red
29 = grey/blue
4
= green/black
17 = grey
30 = pink/blue
5
= brown/red
18 = blue
31 = pink/red
6
= white/red
19 = pink
32 = brown/blue
7
= white/green
20 = white/grey
33 = pink/green
8
= red/blue
21 = yellow/grey
34 = brown
9
= yellow/red
22 = green/red
35 = yellow/pink
10 = grey/pink
23 = white/pink
36 = violet
11 = black
24 = grey/green
37 = white
12 = pink/brown
25 = yellow/brown
13 = yellow/blue
26 = grey/brown
max. 25 m
Id.-Nr. 244 005..
If the connector is to be mounted at the customer's facility, HEIDENHAIN can provide a 37-pin
solderable connector (Id.-Nr. 243 937 ZY).