3.7 Integral PLC
Machine
parameter
Function and input
Change
via
Reaction
Page
PLC-program from RAM or from EPROM
Entry: 0 or 1
0 = EPROM-operation
1 = RAM-operation
Path dependent lubrication
Entry: 0 to 65 535
[units of 65 536 µm]
Value for Timer T0 to T47
Entry: 0 to 65 535 [PLC-cycles]
(TNC 415: 20 ms; TNC 407: 24 ms)
Pre-set value for counters C0 to C31
Entry: 0 to 65 535 [PLC cycles]
Fast PLC input to suppress the monitoring
functions
Entry: 0 to 255 [No. of the PLC input]
Activation condition for fast PLC input from
MP4130
Entry: 0 or 1
Set a number in the PLC (D768 to D956)
Entry: –99 999.9999 to +99 999.9999 [mm] or [°]
Machine parameter with multiple function
Entry: 10 to 30 000
–
Feed rate for returning to the contour
To set a number in the PLC in the word range
W960 to W968
Set a number in the PLC (Module 9032)
Entry: –99 999.9999 to +99 999.9999
Set a number in the PLC (Module 9032)
Entry: –99 999.9999 to +99 999.9999
Set a number in the PLC ( W976 to W988)
Entry: 0 to 65 535
Activation of analogue inputs
Entry: %xx
Bit 0 = 0 no analogue inputs on 1st extension
1 analogue input on 1st extension
Bit 1 = 0 no analogue inputs on 2nd extension