HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 673
For the file type, when transferring with Block Check Characters (see paragraph 2.4.1
"Saving/reading files"), an ASCII character must be entered for the file which is being output or input.
With an input value of nought, the TNC automatically enters the correct type of file in the file header.
MP5202
MP5202.0
MP5202.1
MP5202.2
ASCII character for file type for data input
In mode EXT 1
In mode EXT 2
In mode EXT 3 (PLC)
Input range: 0 to 127
MP5204
MP5204.0
MP5204.1
MP5204.2
ASCII character for file type for data output
In mode EXT 1
In mode EXT 2
In mode EXT 3
Input range: 0 to 127
Example: If a DIN/ISO program is to be output in operating mode EXT2, MP5204.1 = 68 (='D') must
be set (or MP5204.1=0).
The ASCII characters for input and output identification can also be freely defined.
If the machine parameters concerned are loaded with nought, the standard settings apply
(E=Input/A=Output).
MP5203
MP5203.0
MP5203.1
MP5203.2
ASCII character for input identification (E)
In mode EXT 1
In mode EXT 2
In mode EXT 3 (PLC)
Input range: 0 to 127
MP5205
MP5205.0
MP5205.1
MP5205.2
ASCII character for input identification (E)
In mode EXT 1
In mode EXT 2
In mode EXT 3 (PLC)
Input range: 0 to 127