7-20

TNC 407/TNC 415/TNC 425

2 Program creation

01.98

Example:

NC program

0 BEGIN PGM 5 MM
.
.
.
11 FN19:PLC =+20.25/+100
.
.
.
33 END PGM 5 MM

PLC program

.
.
.
LN M2149

;Strobe signal/Transfer

R M2611

;Acknowledgement

.
.
.
L M2149

;Strobe signal/Transfer

CMT 199
.
.
.
LBL 199
L D280

;1st value from FN19

= D120

;Internal buffer 1st value

.
.
.
L D284

;2nd value from FN19

= D124

;Internal buffer 2nd value

L M2149

;Change signal for transfer

S M2611

;Acknowledgement

After the program has been performed, the following data will be in the Doublewords D120 and
D124 :

D120 = 202 500
D124 = 1 000 000

M2150 = 0, since program no. 5 was programmed in mm