Example:
NC program
0 BEGIN PGM 5 MM
.
.
.
11 FN19:PLC =+20.25/+100
.
.
.
33 END PGM 5 MM
PLC program
.
.
.
LN M2149
;Strobe signal/Transfer
R M2611
;Acknowledgement
.
.
.
L M2149
;Strobe signal/Transfer
CMT 199
.
.
.
LBL 199
L D280
;1st value from FN19
= D120
;Internal buffer 1st value
.
.
.
L D284
;2nd value from FN19
= D124
;Internal buffer 2nd value
L M2149
;Change signal for transfer
S M2611
;Acknowledgement
After the program has been performed, the following data will be in the Doublewords D120 and
D124 :
D120 = 202 500
D124 = 1 000 000
M2150 = 0, since program no. 5 was programmed in mm