beautypg.com

5 selecting kv factors with m105/m106, 5 selecting k – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 287

background image


4-162

TNC 407/TNC 415/TNC 425

7 M-functions

01.98

7.5 Selecting K

v

factors with M105/M106

A second set of Kv factors is selected with M-function M105. These Kv factors are defined in
machine parameters MP1515.x (feed precontrol) and MP1815.x (lag mode). Selecting a higher Kv
factor can selectively enhance the contour accuracy. M105 influences the compensation of reversal
spikes during circular movement. M105 activates the machine parameters MP715 and MP716. The
original set of K

v

factors is restored by the M-function M106. M-functions M105/M106 are enabled

by MP7440, Bit 3.

MP7440

Activating M-functions
Entry: %xxxxx

Bit 0

Program halt at M06

0 = program halt at M06
1 = no program halt at M06

Bit 1

Modal cycle call M89

0 = normal code transfer from
M89 at start of block
1 = modal cycle call M89 at end of block

Bit 2

Program run hold with

0 = program run hold until feedback of

M-functions

M-function
1 = no program run hold
(no waiting for feedback)

Bit 3

Select K

v

factors with

0 = function not active

M105/M106

1 = function active

Bit 4

Reduced feed-rate in the

0 = function not active

tools with M103 F...

1 = function active