Mounting and electrical installation, Hardware, 2 mounting and electrical installation – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 717: 1 hardware

01.98
TNC 407/TNC 415/TNC 425
2 Mounting and electrical installation
11-3
2 Mounting and electrical installation
The connection conditions are the same as for the TNC 415 B´ – the differences between TNC 425
and TNC 415 B are explained in the following sections.
2.1 Hardware
The TNC 425 consists of the following hardware components:
•
LE 425
(logic unit)
•
TE 400
(TNC control panel)
•
BC 110 B
(VDU)
•
PL 410
(max. 2 PLC I/O units as option)
The following Identification Numbers have been allocated for the LE 425 so far:
ID Number
Logic Unit
Modification
267 214 19
LE 425
267 214 24
LE 425
with "Digitise TS 120" module
267 214 28
LE 425 E
267 214 38
LE 425 E
Export
267 214 39
LE 425
Standard
267 214 44
LE 425
with "Digitise TS 120" module
267 214 47
LE 425
with "Digitise TM 110" module
267 214 48
LE 425 E
Export
267 214 49
LE 425
Standard
267 214 54
LE 425
with "Digitise TS 120" module
267 214 57
LE 425
with "Digitise TM 110" module
267 214 58
LE 425 E
Export
267 214 59
LE 425
Standard
Identification number for software module "Digitizing with TS 120": 246 051 01