HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 303

MP6321
Measuring the centre offset when calibrating the TM 110
Entry:0 or 1
0 = Calibration with measuring the centre offset
1 = Calibration without measuring the centre offset
MP6361
Rapid traverse in the touch probe cycle (measuring touch probe)
Entry: 10 to 10
000 [mm/min]
MP6160
Spindle orientation 180
°
rotation
Entry:
–1 to 88
–1
= Spindle orientation directly through NC
0
= Function not active
1 to 88 = Number of the M function for spindle orientation by PLC
MP7411
Tool data in touch probe block
Entry: 0 or 1
0 = With the touch probe block the current tool data are overwritten with the
calibrated data of the probe system.
1 = The current tool data are retained even with a touch probe block.
Marker
Function
Set
Reset
M2502
NC STOP with deflected stylus in all modes (not TS 511)
PLC
PLC
M2503
Enable marker for probing functions
NC
PLC
M2022
Touch probe not ready (no standby signal at connector X12
or signals from TM 110 are faulty)
NC
NC
M2023
Stylus deflected before start of probing cycle
NC
NC
M2025
Stylus deflected (probing sequence is executed)
NC
PLC
M2026
Probing sequence ended or interrupted
NC
NC
M2027
Low battery voltage (battery warning at connector X12);
only evaluated during the probing sequence)
NC
NC
M2499
Open the spindle control loop
PLC
PLC
M2127
Spindle in motion
NC
NC