beautypg.com

HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 28

background image


2-24

TNC 407/TNC 415/TNC 425

3 Software

01.98

TNC 415 B/TNC 425:

280 54x 03

TNC 415 F/TNC 425 E:

280 56x 03

TNC 407:

280 58x 03

This version was never released.

TNC 415 B/TNC 425:

280 54x 04

TNC 415 F/TNC 425 E:

280 56x 04

TNC 407:

280 58x 04

Release 3/95

New functions:

To make changes to the tool table it is no longer necessary to transfer the entire tool table. It now
suffices to transfer only those tool data that have changed. These partial data can be transferred in
the Program Run mode of operation

For a rotary table display that is set to modulo 360°, the M function M 126 positions the table by
the shortest path. M 127 positions the table, as before, by the path that does not cross over the 0°
position.

The function for automatic tool measurement was expanded with the TT 110. The new fields
L-OFFS, R-OFFS, LBREAK and RBREAK were introduced to the tool table (MP7266.19 to MP7266.21).
In addition, in Cycle 31 the radius is no longer entered and the fields L-OFFS, R-OFFS, LBREAK and
RBREAK were added to the modules 9092, 9093 and 9094. The new marker M2393 is set whenever
the break tolerance is exceeded.