7/95 TNC 407/TNC 415/TNC 425 16 Commissioning and start-up procedure 4-271

Connect storage oscilloscope to

tachometer of servo-amplifier of X axis.

Enter following program in

"PROGRAMMING AND EDITING"

operating mode:

LBL 1
X 100

1)

R0 F MAX

X 0 R0 F MAX
CALL LBL 1 REP 100/100

Press machine START button in the

"PROGRAM RUN/SINGLE BLOCK"

operating mode.

Machine runs.

MP1520: Increase entry value until overshoot occurs.

MP1520: Reduce entry value until overshoot stops.

U [V]

t [ms]

Check axes Y, Z, IV and V and correct MP1520, if necessary.

U [V]

t [ms]

1)

Program the traverse paths for the axis concerned as large as possible.