beautypg.com

2 general data transfer (strobes) – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 484

background image


01.98

TNC 407/TNC 415/TNC 425

2 Program creation

7-23

MP4210.0

Set a number in the PLC

to MP4210.47

Entry : –99 999.9999 to +99 999.9999

MP 4220

Machine parameter with multiple function
Entry : 80 to 30 000
- Set a number in the PLC. In Word range W960 to W968.
- Feed rate for re-approaching the contour

MP4220.0 X axis
MP4220.1 Y axis
MP4220.2 Z axis
MP4220.3 axis 4
MP4220.4 axis 5

MP4310.0

Set a number in the PLC, in the Word range W976 to W988

to MP4310.6

Entry : 0 to 65 535

MP4230.0

Set a number in the PLC (Module 9032)

to MP4230.31

Entry : - 99 999.0000 to +99 999.9999

MP4231.0

Set a number in the PLC (Module 9032)

to MP 4231.31

Entry : - 99 999.0000 to +99 999.9999

2.3.2 General data transfer (Strobes)

The NC transfers general data to the PLC, e.g. M functions, S word, T word, G code.

The transfer is controlled by strobes.

Example:

When an M function is output, the NC sets the strobe signal M2045. After evaluating the M
function, the PLC sets the acknowledge marker M2482. The PLC must reset M2482 otherwise no
further strobes can be transferred by the NC.