beautypg.com

3 software types 259 93, 259 94 and 243 03 – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 22

background image


2-18

TNC 407/TNC 415/TNC 425

3 Software

01.98

3.5.3 Software types 259 93, 259 94 and 243 03

TNC 415 B/TNC 425:

259 93x 04

TNC 415 F/TNC 425 E:

259 94x 04

Release 11/92

New functions:

New functions for programmed contour approach and withdraw

"Working Plane" cycle for machines with swivel head

"Contour Train" cycle

"Scaling factor axis-specific" cycle

Three-dimensional tool compensation in DNC mode

Extended tool management

Extended additional status displays for file information, positions, tool data and coordinate
transformation

Stiction compensation

PLC axes

Extended PLC command set

Length of filenames increased to 16 characters

Automatic correction of centre offset for probe system

Oscilloscope function

New organization for PLC files

Additional machine parameters for data transfer to PLC

BACKUP and RESTORE functions

Q parameter for tool length (Q114)

Axis positions after programmed probe cycle in Q parameters Q115 to Q119

New input format for machine parameters

TNC 415 B/TNC 415:

259 93x 05

TNC 415 F/TNC 425 E:

259 94x 05

Release 11/93

New functions:

Status information can now be read with module 9035. See "TNC 407/TNC 415 B/TNC 425
Description of the Differences from TNC 415".

The minimum input range of machine parameters MP6120, MP6350, MP6360 has been changed
from 80 mm/min to 10 mm/min.

MP7300 has been extended as follows:

MP7300

Delete status display, Q parameter and tool data
Entry: 0 to 7
0 = delete status display, Q parameter and tool data when selecting a program
1 = delete status display, Q parameter and tool data with M02, M30, END PGM

and selecting a program

2 = delete status display and tool data when selecting a program
3 = delete status display and tool data with M02, M30, END PGM and selecting a
program
4 = delete status display and Q parameter when selecting a program
5 = delete status display and Q parameter with M02, M30, END PGM and

selecting a program

6 = delete status display when selecting a program
7 = delete status display with M02, M30, END PGM and selecting a program